SK 100 G2, SK 300 G2, SK 500 G2
02/2005 5/27
2 Technical data
2.1 General
Power supply voltage __________________ 2 batteries, type mignon AA; 1.5V
or battery pack BA 2015; 2.4V
Nominal voltage ______________________ +2.4V
DC
Operating voltage _____________________ +1.8V
DC
to +3.1V
DC
Switch-off threshold
when powered by batteries _________ +1.8V
DC
when powered by BA 2015 accupack__ +2.0V
DC
Switch-on threshold ___________________ +2.2V
DC
Current consumption
at nominal voltage________________ ≤170mA
with transmitter switched off _______ ≤250µA
Operating time
when powered by batteries
or accupack _____________________ ≥8 hours
Battery status indication________________ 100%, 70%, 30%, low battery
Programming interface _________________ integrated infrared interface
Temperature range ____________________ -10°C to +55°C
Dimensions in mm_____________________ 82 x 63 x 23
Weight incl. batteries __________________ approx. 200g
Compliant with
Europe _________________________CE 0682
USA ___________________________FCC ID: DMOB2EUVL
Canada ________________________IC: 2099A-G2SK
Japan _________________________R202Y2378511; R202Y2378512;
R202B2378531; R202B2378532