Sennheiser SK 500 G2 Manuel d'utilisateur Page 13

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 27
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 12
SK 100 G2, SK 300 G2, SK 500 G2
02/2005 13/27
3 RF module
See “Measuring set-up” page 10.
Removing the RF module:
1. Loosen the lens-head screw on the RF PCB (see exploded view, pos. 22).
2. Remove the RF module (maintain the motherboard connection via flat ribbon cable).
Re-establishing the ground connection between RF module and motherboard:
Connect the M6 point on the component side of the RF PCB and the P4 point on the component side of the motherboard.
For this purpose, solder a stranded wire with a length of 10cm between the points M6 and P4.
3.1 Supply voltage RF
PCB
Supply +2.4 V
DC
via
battery contacts
„POWER“ = ON;
(press button for approx.
3 seconds)
RF module
TP72/GND
+5.1V
DC
to
+5.35V
DC
See page 27
3.2 Transmission
frequency
See 3.1 Pilot = „OFF“
Mute = Aus
Without
antenna at
TP8/ direkt
ground GND
Transmission
frequency =
receive
frequency
±10kHz
See 3.4
Avoiding
measuring
errors
3.3 Measuring / balancing the PLL voltage
Attention
The buttons S204, S206, S202, and S208 on the motherboard may be damaged, if you press them using sharp-edged or
pointed objects (e.g. the tip of a ballpoint pen). Only use objects with end-rounded tips that will not damage the buttons.
3.3.1 Centre range limit See 3.1 Use „TUNE“ to set the
centre transmission
frequency
TP3 +2.5V
DC
to
+2.9V
DC
Balancing via
C114
3.3.2 Lowest range limit See 3.1 Use „TUNE“ to set the
lowest transmission
frequency
TP3 +0.9V
DC
to
+2.3V
DC
Balancing via
C114
3.3.3 Uppermost range
limit
See 3.1 Use „TUNE“ to set the
uppermost transmission
frequency
TP3 +2.9V
DC
to
+4.2V
DC
Balancing via
C114
3.4 Measuring / balancing the RF output power
How to avoid measuring errors:
1. Desolder the antenna before starting the measurement.
2. Measure against a direct ground point on TP8.
3. Only use shielded measuring lines with an impedance of 50O and a length of 50cm.
3.4.1 Mean RF output
power
See 3.1 Spectrum analyser or
power measuring device;
set centre transmission
frequency (ft=fm)
Without
antenna to
TP8 / direct
ground GND;
Japan: J200
test socket
15mW to
38mW /
12dBm to
15.8dBm
Japan: 5mW to
10mW / 7dBm
to 10dBm
3.4.2 Highest RF output
power
See 3.1 Spectrum analyser or
power measuring device;
set highest transmission
frequency (ft=fh)
3.4.3 Lowest RF output
power
See 3.1 Spectrum analyser or
power measuring device;
set lowest transmission
frequency (ft=fl)
3.5 Nominal deviation
LINE
AF generator at jack
socket (1kHz, 270mV)
Set „SENSIT“ to -10dB See 3.4.1 < ±24kHz Pay attention
to the pin
assignment of
the jack socket:
See “Measu-
ring set-up”
page 10.
3.6 Peak deviation LINE AF generator at jack
socket (1kHz, 1.08V)
Set „SENSIT“ to -10dB See 3.4.1 < ±4kHz
Japan:
±40kHz
3.7 S/N ratio referring
to peak deviation
24kHz
Mod: OFF
AF level meter
MUTE= „ON“
See 3.4.1
60dB(A)
eff
3.8 THD at nominal
deviation
See 3.4 AF level meter
THD measuring
Mod: ON
See 3.4.1 0.08% to 1.2%
Se-
quence
Type of measure-
ment/adjustment
Signal input Device settings Mesuring
point/ test
point
Required
value
Remarks
Vue de la page 12